How to a Wire 3-Way Combination Switch and Grounded Outlet?
Installation of Three-Way Combo Device for Common and Separated Feed
What is a 3-Way Combination Device?
A Three-Way combo device with an outlet is actually the combination of a grounded outlet and a 3-way switch in a single unit (such as Leviton 5245, 5241, 5641 etc.). It can be used for 120V and 240V circuits where a load point (e.g. light bulb) needs to be controlled from two different locations with an additional feature of outlet receptacle.
Construction of 3-Way Combo Device
The following figure shows the basic construction of a 3-Way combination switch & outlet device. It has a total of 6 terminal screws. The two brass screws are for travelers wires while the two black screws are common (hot) which is bonded together by a break-off fin. The break-away fin can be removed to use two separate incoming sources from two different breakers. The silver screw is used for Neutral wire while the green colored screw is used for Grounding wire.
Click image to enlarge
The following figures show the operation of internal contacts in a 3-way combo device (combination of a 3-way switch and an outlet).
Related Posts:
- How to Wire Combo Switch and Outlet? – Switch/Outlet Combo Wiring Diagrams
- How to Wire an Outlet Receptacle? Socket Outlet Wiring Diagrams
Let’s see how to wire these types of switches for different load circuits and applications.
Wiring 3-Way Combo Device with Ordinary 3-Way Switch (Common Feed)
The following wiring diagram shows how to control a light bulb from two places using a 3-way combination switch & outlet and an ordinary 3-way switch using common feed. It clearly shows that the incoming Hot (Line) wire is connected to the common dark screws that are bonded together via break-off fin.
The two brass terminals of the 3-way combo device are wired to the A1 and A2 terminals of a typical 3-way switch via travelers wires. The common terminal of an ordinary 3-way switch is connected to the light bulb.
The Neutral wires are connected to the Neutral (Silver) terminal of the 3-Way Combo device and light bulb. Finally, the ground wires are connected to both switches and a light bulb.
Click image to enlarge
Keep in mind that the outlet in the 3-way combo device is always ON and the light bulb can be switched ON and OFF from two locations using a 3-way and 3-way combo device.
Related Posts:
- How to Wire Combo Switch and Outlet? – Switch/Outlet Combo Wiring Diagrams
- How to Wire an AFCI Combo Switch – AFCI Switch Wiring Diagrams
- How to Wire GFCI Combo Switch and Outlet – GFCI Switch/Outlet Wiring Diagrams
Wiring 3-Way Combo Device with Ordinary 3-Way Switch (Separate Feed)
The following wiring diagram shows how to control a bulb from two different locations using a 3-way combo device and a typical 3-way switch using separate feed.
The wiring diagram is the same as above except the break-away fin removed from the common terminal side of the 3-way combo device. Hence, one screw is connected to Hot 1 (120V from a breaker) and the second dark screw is connected to Hot 2 (120V from another breaker) from the 120/240V main panel.
Click image to enlarge
This way, the outlet is always ON which is fed up by a separate (HOT 2) source while the light bulb controlled from different locations are using separate feed via HOT 1. The rest of the circuit and its operation is the same as above.
Related Posts:
- How to Find the Number of Outlets on a Single Circuit Breaker?
- How to Find Voltage & Ampere Rating of Switch, Plug, Outlet & Receptacle
Controlling a Light Bulb from Two Location using 3-Way Combo Device
The following wiring diagram shows how to control a bulb from two different places using two 3-way combo devices. It clearly shows that the incoming Hot (Line – black wire) wire is connected to the common dark screws that are bonded together via break-away fin of the right side 3-way combo switch and outlet device.
The two brass terminals of both 3-way combo devices are wired through travelers wires. One of the common screws of the left side 3-way combo switch is connected to the light bulb. Finally, both Ground and Neutral wires are connected to the silver and green colored screws of both 3-way combo devices and light bulb respectively.
Click image to enlarge
Keep in mind that the outlet on the right side 3-way combo device is always ON while the receptacle outlet on the left side will only ON when the light bulb is ON. This way, the light bulb can be controlled for switched ON and OFF operations from two places using a two number of 3-way combo devices.
Related Posts:
- How to Wire a UK 3-Pin Socket Outlet? Wiring a BS1363 Socket
- How to Wire a Twin 3-Pin Socket Outlet? Wiring 2-Gang Socket
Controlling a Bulb from Two Places using Two 3-Way Combo Devices (Both Outlets Always ON)
The following wiring diagram shows the controlling of a bulb from two locations using a two number of 3-way combo devices where both outlets are always ON.
The wiring diagram is the same as above except the break-away fin of the left side 3-way combo device has been removed and the upper dark screw is connected to the light bulb and the lower terminal fed-up by common source from the right side of the 3-way combo device. In other words, The Hot line is connected to both 3-way combination switches while the break-away fin has been removed from the left side 3-way combo device.
Click image to enlarge
This way, both the outlets are always ON which is fed up by a common source (Line) while the light bulb is controlled from two different places. The rest of the circuit and its operation is the same as above.
Related Posts:
- How to Control a Lamp by a Single Way or One-Way Switch?
- How to control each lamp by separately switch in parallel lighting circuit?
- The brass screws should be connected to the Hot (line, live or phase) wire using the IEC & NEC Wire color codes. In case of SPDT and 4-Way (Intermediate switches), black colored screws are used for Hot or common terminals. In short, the color for common terminal is different than other terminals.
- The silver screws should be connected to the Neutral wire (in case of switched outlet)
- The green screw should be connected to the ground / earth wire (Green/Yellow or naked wire)
- If there are no color coded screws on outlets, refer to the user manual or contact a licensed electrician.
- Neutral Wire is not required in 240V outlets wiring (US) Also, Neutral is never connected to the switches.
- Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size MCB according to the load rating.
Precautions:
- Switch off the main circuit breaker to make sure the power supply is OFF before wiring an existing or new outlet or switch with an electrical/junction box.
- Contact the authorized and licensed electrician for switch installation if you are not sure about the wiring diagrams.
- The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in the wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous.
Related Posts:
- How To Wire Switches in Series?
- How To Wire Switches in Parallel?
- How To wire Lamps in Series?
- How To Wire Lamps in Parallel?
- How to Control a Lamp by a Single Way or One-Way Switch?
- How to control each lamp by separately switch in parallel lighting circuit?
- How to Wire Single Pole, Double Throw (SPDT) Switch? IEC & NEC
- How to Wire Double Pole, Double Throw (DPDT) Switch? IEC & NEC
- How to Wire 4-Way Switch (NEC) & Intermediate Switch as 3-Way (IEC)?
- How to Wire Single Pole, Single Throw (SPST) Switch? IEC & NEC
- How to Wire Single Pole, Double Throw (SPDT) Switch? IEC & NEC
- How to Wire a Pilot Light Switch? Wiring of 2 & 3 Way Neon Light Switches
- How to Control Water Heater using Switches?
- How to Wire a Ceiling Fan? Dimmer Switch and Remote Control Wiring
- How to Wire Auto & Manual Changeover & Transfer Switch – (1 & 3 Phase)
- Automatic Bathroom Light Switch Circuit Diagram and Operation
- Staircase Wiring Circuit Diagram – How to Control a Lamp from 2 Places by 2-Way Switches?
- 2 Way Switch – How to Control One Lamp From Two or Three Places?
- How to Control One Light Bulb from Six Different Places using 2-Way & Intermediate Switches?
- Corridor Wiring Circuit Diagram – Hallway Wiring using 2-Way Switches
- Hospital Wiring Circuit for Light Control using Switches
- Tunnel Wiring Circuit Diagram for Light Control using Switches
- Godown Wiring Diagram -Tunnel Wiring Circuit and Working
- Hostel Wiring Circuit Diagram and Working
- How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug
- Switch and Push Button Symbols
- Basic Electrical Wiring Diagrams