Basic ConceptsCircuit AnalysisDC CircuitsHow ToQuestions - Answers

Norton’s Theorem. Easy Step by Step Procedure with Example

Norton’s Theorem in DC Circuit Analysis

Norton’s theorem is another useful technique to analyze electric circuits like using the Thevenin’s Theorem, which reduces linear, active circuits and complex networks into a simple equivalent circuit. The main difference between Thevenin’s theorem and Norton’s theorem is that, Thevenin’s theorem provides an equivalent voltage source and an equivalent series resistance, while Norton’s theorem provides an equivalent Current source and an equivalent parallel resistance.

Norton’s Theorem states that:

Any linear electric network or complex circuit with current and voltage sources can be replaced by an equivalent circuit containing a single independent current source IN and a parallel resistance RN.

In other but simple words, Any linear circuit is equivalent to a real and independent current source in specific terminals.

Related Post: Thevenin’s Theorem. Easy Step by Step Procedure with Example (Pictorial Views)

Steps to Analyze an Electric Circuit using Norton’s Theorem

  1. Short the load resistor.
  2. Calculate / measure the Short Circuit Current. This is the Norton Current (IN).
  3. Open Current Sources, Short Voltage Sources and Open Load Resistor.
  4. Calculate /measure the Open Circuit Resistance. This is the Norton Resistance (RN).
  5. Now, Redraw the circuit with measured short circuit Current (IN) in Step (2) as Current Source and measured open circuit resistance (RN) in step (4) as a parallel resistance and connect the load resistor which we had removed in Step (3). This is the Equivalent Norton Circuit of that Linear Electric Network or Complex circuit which had to be simplified and analyzed. You have done it.
  6. Now find the Load current flowing through and Load Voltage across Load Resistor by using the Current divider rule. IL = IN / (RN / (RN+ RL)) ((For clear explanation … check the solved example given below).

Solved Example by Norton’s Theorem:

Example:

Find RN, IN, the current flowing through and Load Voltage across the load resistor in fig (1) by using Norton’s Theorem.

Norton's Theorem. Easy Step by Step Procedure with Examples and solved problems
Norton’s Theorem: Step by Step Procedure with Examples

 Solution:-

STEP 1.

Short the 1.5Ω load resistor as shown in (Fig 2).

Norton’s theorem

STEP 2.

Calculate / measure the Short Circuit Current. This is the Norton Current (IN).

We have shorted the AB terminals to determine the Norton current, IN. The 6Ω and 3Ω are then in parallel and this parallel combination of 6Ω and 3Ω are then in series with 2Ω.

So the total resistance of the circuit to the Source is:-

2Ω + (6Ω || 3Ω) ….. (|| = in parallel with).

RT = 2Ω + [(3Ω x 6Ω) / (3Ω + 6Ω)] → IT = 2Ω + 2Ω = 4Ω.

RT = 4Ω

IT = V ÷ RT

IT = 12V ÷ 4Ω

IT = 3A..

Now we have to find ISC = IN Apply CDR… (Current Divider Rule)…

ISC = IN = 3A x [(6Ω ÷ (3Ω + 6Ω)] = 2A.

ISC = IN = 2A.

norton equivalent circuit examples

STEP 3.

Open Current Sources, Short Voltage Sources and Open Load Resistor. Fig (4)

norton equivalent circuit examples

STEP 4.

Calculate /measure the Open Circuit Resistance. This is the Norton Resistance (RN)

We have Reduced the 12V DC source to zero is equivalent to replace it with a short in step (3), as shown in figure (4)  We can see that 3Ω resistor is in series with a parallel combination of 6Ω resistor and  2Ω resistor. i.e.:

3Ω + (6Ω || 2Ω) ….. (|| = in parallel with)

RN = 3Ω + [(6Ω x 2Ω) ÷ (6Ω + 2Ω)]

RN = 3Ω + 1.5Ω

RN = 4.5Ω

Norton Theorem

STEP 5.

Connect the RN in Parallel with Current Source Iand reconnect the load resistor. This is shown in fig (6) i.e. Norton Equivalent circuit with load resistor.

Norton Equivalent circuit
Norton Equivalent Circuit

STEP 6.

Now apply the last step i.e. calculate the load current through and Load voltage across the load resistor by Ohm’s Law as shown in fig 7. 

Load Current through Load Resistor…

IL = IN x [RN ÷ (RN+ RL)]

= 2A x (4.5Ω ÷ 4.5Ω + 1.5Ω) → = 1.5A

IL = 1. 5A

And

Load Voltage across Load Resistor…

VL = IL x RL

VL = 1.5A x 1.5Ω

VL= 2.25V

Finding the Load Current and Load Voltage through Norton's Theorem
Finding the Load Current and Load Voltage through Norton’s Theorem

Now compare this simple circuit with the original circuit given in figure 1. Can you see how much easier it will be to measure/calculate the load current and load Voltage for different load resistors through Norton’s Theorem even in much more complex circuits? Only and only yes.

Good to know: Both Norton’s & Thevenin’s theorems can be applied to both AC and DC circuits containing difference components such as resistors, inductors and capacitors etc. Keep in mind that the Norton’s current “IN” in AC circuit is expressed in complex number (polar form) whereas, the Norton’s resistance “RN” is stated in rectangular form.

Related Posts:
➡️ READ FULL ARTICLE 📖

Electrical Technology

All about Electrical and Electronic Engineering & Technology. Join us on WhatsApp at Electrical Technology Official Channel, to receive the latest content, articles, and updates. You can also like and follow our social media networks below, or subscribe with your email to receive premium engineering articles in your mailbox.

24 Comments

  1. anas mamji says:

    sir plz give me a name of books about circuit and analysis of network for clearing concepts.<br />

    1. Quadri Syed Mujtaba says:

      WH Hayt and JE Kemmerly
      Engineering circuit analysis

    2. javed usmani says:

      basic electronics by b l theraja

      1. Khushal Jadhao says:

        If we have to find the current through voltage source with 10ohm resistir are connected in series then how to find the Zl i.e load impedence

  2. Electrician Brisbane says:

    Great article! Norton&#39;s Theorem can certainly be confusing for a beginner.

  3. Anonymous says:

    great and thanku<br />

  4. DINABANDHU PARAI says:

    I want to know the best refarance book which can give me the best concept about nortons / Thevein , super position theorem
    If u can pls help me
    Thank you

  5. Pls,why did they use (3/(3 6)) to solve for the nortons cuRrent

  6. fatima jawadu says:

    May you please help with the best book I can use for electrical engineering technology

    1. Naveed khan says:

      Sadique 11th edition

  7. Varun Chauhan says:

    Thanks dude…..i hve exam in 3 hrs……ur post’s helped me a lot!!!

    1. Electrical Technology says:

      I’m glad it helped you. Lots of best wishes & prayers for your success!

  8. Ankur Kumar says:

    Thanks sir a lot of thanks

  9. jomari Honrado says:

    why the CDR are not (RT / RX+RT) X IT make me confuse ?

  10. What if u r to find the current across the 6(ohm) resister?

  11. Nortom resistence is not calculated correctly mine give 4.5 ohm, you have calculated as seen from the battery

  12. Very informative. really good website. never thought I would get hand made notes like content on a website. Keep it up guys.

  13. Marvellous says:

    Thanks for your clear information ??

  14. Rushikesh says:

    Stepwise answer is very important and you do it well .i understand the problems easily .

  15. NevrOnline says:

    The bestt explanation i have come across so far..thank youu mann

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button

Kindly permit ads on our free website.

It appears that you are using an ad blocker. We rely on advertising to support our website, provide free information, and sustain our services. Kindly consider whitelisting our website to allow ads.