Overhead Lines
-
Overhead Lines
What Does Hanging Shoes from Overhead Power Lines Mean?
What are the Reasons Behind Shoes Strung Up on Power Lines? You may have seen colorful aerial marker balls on power lines, but what does it mean when shoes are…
Read More » -
Overhead Lines
Why is the Position of Overhead Conductor Exchanged in a Transposition Tower?
Why are Overhead Conductor Positions Exchanged in a Transposition Tower? Electrical energy is transmitted in high-voltage three-phase lines without a neutral (3 conductors). Over long distances, these lines develop reactances,…
Read More » -
Overhead Lines
Why is Live Line-Washing or Cleaning Done on Energized Power Lines?
Importance of Live-Line Washing, Live-Line Maintenance or Cleaning What is Live-Line Washing? Live-line washing, also known as live-line maintenance or live-line working, is a technique used in the maintenance of…
Read More » -
Overhead Lines
How Does Temperature Impact Sag in Overhead Lines?
Effects of Temperature on Sag in an Overhead Line The sag in an overhead line, which refers to the vertical distance between a conductor and the straight line between its…
Read More » -
Power System
Why is Power Transmitted at High Voltage Instead of High Current?
Why is High Voltage Used for Power Transmission and Not Lower Voltage? Transmitting electrical power at high voltage and low current is a more efficient and economical approach for long-distance…
Read More » -
Overhead Lines
What is the Power Angle in a Power Transmission Line?
What Is the Power Angle in Transmission Lines, and How Do You Calculate It? The power angle (denoted by δ) is the phase angle difference between two voltage levels in…
Read More » -
Overhead Lines
What is Sag in Overhead Power Transmission Lines?
Calculation of Sag in Overhead Transmission Lines What is Sag? Sag in overhead power transmission line refers to the natural, downward curvature or dip that occurs in the power lines…
Read More » -
Overhead Lines
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Above the Phase Lines in the Overhead Transmission Line? The ground wire (also known as earth wire or OPGW) above the phase lines in overhead…
Read More » -
Overhead Lines
What is the Minimum Ground Clearance for Overhead Power Line?
Minimum Ground Clearance Standard of Sag Due to safety reasons, an adequate distance is always maintained between the overhead conductor and the ground, depending on the transmission or distribution voltage.…
Read More » -
Overhead Lines
How Many Poles and Towers are Situated Within a 1-km Span?
How Many Utility Poles and Transmission Towers are Located Within a 1-kilometer Distance? The number of electricity poles for distribution and towers for power transmission in a 1-kilometer distance can…
Read More »