Main Service Panel
-
Protection
Why Do We Need a GFCI & How Does it Protect During Faults?
Why Do We Need a GFCI Breaker and How Does it Protect During Ground Faults? A Ground Fault Circuit Interrupter (GFCI) is designed to protect circuits by detecting electrical faults…
Read More » -
Protection
How Does a Standard Breaker Respond to Electrical Fault?
How Does an Ordinary Circuit Breaker Operates During Short Circuit, Overload & Ground Faults? When a standard circuit breaker detects a fault, such as an overload or short circuit, it…
Read More » -
Protection
Why Doesn’t a Standard Breaker Protract Against Ground Faults?
Why Does a Standard Breaker Pose a Shock Hazard with a Broken Neutral? A broken neutral in a circuit with a standard breaker can pose a shock hazard because the…
Read More » -
Protection
How Do GFCI and Standard Breakers Respond to Ground Faults?
How Does a GFCI Breaker Protect Us in Case of a Fault, Compared to Standard Breakers? An ordinary circuit breaker in the main panel for household appliances protects only in…
Read More » -
Protection
What Happens if the Neutral is Lost in the Main or Subpanel?
What Will Happen When the Neutral is Broken in the Main Panel or Subpanel? The neutral wire provides a return path for current back to the power source, completing the…
Read More » -
Protection
Why Must Neutral and Ground Wires Be Bonded in the Main Panel?
Why Do Neutral and Ground Conductors Need to Be Bonded in the Main Panel? According to NEC Article 250, both the neutral and ground wires must be connected only in…
Read More » -
Protection
Why are Neutral and Ground Wires Separated in a Subpanel?
Why Do Neutral and Ground Conductors Need to Be Separated in a Subpanel? According to NEC Article 250, neutral and ground wires must remain separate in subpanels. Bonding (connecting) the…
Read More » -
Electrical Wiring
National Electrical Code (NEC) Requirements for Panelboards
NEC Requirements for Electric Main Panelboards and Working Space Depth and Mounting Height Panelboards shall be installed in accordance with the listing of the panelboard. The National Electrical Code (NEC)…
Read More » -
Electrical Wiring
How to Determine the Right Size Capacity of a Subpanel?
Sizing the Suitable Capacity of a Subpanel or Main Lug A subpanel or main lug (also known as a remote panel in the NEC) is a smaller service panel installed…
Read More » -
Electrical Wiring
How to Determine the Number of Circuit Breakers in a Panel Board?
How to Calculate the Number of Circuit Breakers for a Home Load Center and Distribution Board Based on the Load Calculation? In the USA and Canada, the common supply voltage…
Read More »