Grounding
-
Protection
How to Test Earthing – Grounding System using a Light Bulb?
How to Check the Grounding or Earthing System at Home using a Light Bulb? In today’s tutorial, we will demonstrate how to test and check the earthing or grounding system…
Read More » -
Protection
How to Test Grounding / Earthing System using a Multimeter?
How to Check Earthing and Measure Ground Resistance using a Multimeter? Measuring ground resistance using a multimeter is generally not as accurate as using specialized ground resistance testers, but it…
Read More » -
Protection
How to Test and Measure the Ground Resistance using a Megger?
How to Check Earthing and Measure Ground Resistance using Megger Earth Tester? A Megger, or Megohmmeter (also known as Megger earth tester), is a specialized instrument commonly used for insulation…
Read More » -
Protection
How to Measure Ground Resistance? – Testing Earth Resistance
How to Measure the Earth – Ground Resistance using Different Methods? Grounding, also known as earthing, is a safety practice and technical technique that involves connecting electrical systems and equipment…
Read More » -
Protection
Why is Copper Rod Used as Ground Rod in Grounding / Earthing System?
Why is Solid Copper Rod Preferred to use in Earthing / Grounding Instead of Iron, Steel etc.? While copper is a common choice for grounding rods, other materials like aluminum,…
Read More » -
Protection
What is Ground Rod and How to Install a Ground Electrode in Grounding System?
Ground Rod in Grounding System – Size, Role, Types, Installation and Applications What is a Ground Rod? A ground rod, also known as an earthing rod, grounding rod or ground…
Read More » -
Protection
Why is the Grounding Wire Bare and Not Insulated?
Why is Mostly Solid Bare Conductor Used for Grounding Instead of Insulated Wire? A ground wire, also known as a grounding wire or ground conductor, as the name implies, is…
Read More » -
Protection
Why are Salt and Charcoal Added in Earthing Pit for Grounding?
Why We Must Put Charcoal and Salt for Earthing and Grounding? For proper earthing and grounding, it is very important to maintain low resistance of grounding / earthing conductors by…
Read More » -
Protection
Difference Between Grounding, Earthing and Bonding
What is the Difference between Earthing, Grounding and Bonding? There is unusual confusion to understand the basic concept and main difference among grounding, earthing and bonding even some professionals interchange…
Read More » -
Comparisons
What is the Difference Between Neutral, Ground and Earth?
The Main difference between Neutral, Ground and Earth? To understand the difference between Neutral, Ground and Earth, we must first understand the purpose of these elements. Neutral Neutral is the return…
Read More »