Ground Wire
-
Measuring Instruments
What is Ground Resistance Tester – Working of Ground or Earth Tester
Earth – Ground Resistance Tester – Construction, Working and Applications Earth or ground resistance testers play a vital role in assessing the effectiveness of grounding and earthing systems by measuring…
Read More » -
Protection
Why is Copper Rod Used as Ground Rod in Grounding / Earthing System?
Why is Solid Copper Rod Preferred to use in Earthing / Grounding Instead of Iron, Steel etc.? While copper is a common choice for grounding rods, other materials like aluminum,…
Read More » -
Protection
What is Ground Rod and How to Install a Ground Electrode in Grounding System?
Ground Rod in Grounding System – Size, Role, Types, Installation and Applications What is a Ground Rod? A ground rod, also known as an earthing rod, grounding rod or ground…
Read More » -
Overhead Lines
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Above the Phase Lines in the Overhead Transmission Line? The ground wire (also known as earth wire or OPGW) above the phase lines in overhead…
Read More » -
Overhead Lines
Why are Overhead Power Transmission Lines Not Insulated?
Why Use Bare Conductors for Overhead Transmission Lines Instead of Insulated Conductors? You may have noticed that we use insulated cables for underground power transmission, as well as in industrial…
Read More » -
Protection
Why is the Grounding Wire Bare and Not Insulated?
Why is Mostly Solid Bare Conductor Used for Grounding Instead of Insulated Wire? A ground wire, also known as a grounding wire or ground conductor, as the name implies, is…
Read More » -
Protection
Electrical Grounding and Earthing – Methods, Types and Installation
Electrical Earthing & Grounding – Components, Methods & Types of Earthing – Electrical Grounding Installation According to NEC and IEC What is Electrical Grounding or Earthing? Earthing, also known as…
Read More » -
Overhead Lines
What is the Purpose of Ground Wire in Overhead Transmission Lines?
The Role of Earth Wire or Ground Wire in Overhead Power Lines Ground wire or earth wire (also known as OPGV) is a bare conductor supported at the top of…
Read More »