Ground Wire
-
Protection
Why is the Ground Wire Size Smaller than the Hot Wire?
Why is the Size of the Ground Conductor Smaller than the Line Conductor? The ground wire does not always have to be the same size as the power (phase or…
Read More » -
Protection
Will I Get an Electric Shock If I Touch the Ground Wire?
Is It Harmful to Touch the Grounding Wire? What is the Ground Wire? A ground wire, also known as an earth wire or grounding wire, is a wire in an…
Read More » -
Protection
Protective Multiple Earthing (PME) – TN-C-S – (MEN) and PNB
TN-C-S PME and PNB Earthing Systems AKA Grounding Electrode System What is Protective Multiple Earth (PME)? A protection method where the earth continuity conductor (ground wire) in a consumers premises…
Read More » -
Protection
How to Test Earthing – Grounding System using a Light Bulb?
How to Check the Grounding or Earthing System at Home using a Light Bulb? In today’s tutorial, we will demonstrate how to test and check the earthing or grounding system…
Read More » -
Protection
How to Test Grounding / Earthing System using a Multimeter?
How to Check Earthing and Measure Ground Resistance using a Multimeter? Measuring ground resistance using a multimeter is generally not as accurate as using specialized ground resistance testers, but it…
Read More » -
Measuring Instruments
How to Measure Earth Loop Resistance Using Ammeter and Voltmeter?
How to Measure Earth Loop Impedance Using Ammeter and Voltmeter? Purpose of measuring earth loop resistance is essentially to determine the resistance of the path through which current flows towards…
Read More » -
Protection
How to Test and Measure the Ground Resistance using a Megger?
How to Check Earthing and Measure Ground Resistance using Megger Earth Tester? A Megger, or Megohmmeter (also known as Megger earth tester), is a specialized instrument commonly used for insulation…
Read More » -
Protection
How to Measure Resistivity of Earth Using Wenner Method?
Wenner 4-Point Method for Testing the Specific Resistance of Soil What is Wenner 4-Point Test? The Wenner Method (named after Dr. Frank Wenner of the US Bureau of Standards in…
Read More » -
Protection
How to Test the Earth Fault Loop Impedance – Various Methods
Testing and Measuring Earth Fault Loop Impedance using Different Methods What is Earth Fault Loop Impedance (EFL)? Earth fault loop impedance refers to the electrical resistance in the earth path…
Read More » -
Protection
How to Measure Ground Resistance? – Testing Earth Resistance
How to Measure the Earth – Ground Resistance using Different Methods? Grounding, also known as earthing, is a safety practice and technical technique that involves connecting electrical systems and equipment…
Read More »
- 1
- 2