Electrical Wiring
-
Electrical Wiring
How to Wire Single Pole, Single Throw (SPST) as 2-Way Switch?
Installation of SPST – 2-Way Switch (NEC) AKA 1-Way Switch (IEC) for 120/240V & 230V AC – 2-Way & 1-Way Circuits What is SPST Switch? SPST (stands for Single Pole…
Read More » -
Electrical Wiring
Top & Best Books & Guides for Electricians and Apprentices
Best Books for Electricians and Apprentices in 2022 The following list provides a series of authentic books and guides which will properly help you to become an ultra pro max…
Read More » -
Protection
ELCB (Earth Leakage Circuit Breaker) – Construction, Types & Working
What is an ELCB? Types, Working, and Application of Earth Leakage Circuit Breaker ELCB or Earth Leakage Circuit Breaker is a protection device that protects against earth leakage. Initially, the…
Read More » -
Protection
AFCI: Arc Fault Circuit Interrupter. Types, Working & Applications
What is an AFCI (Arc Fault Circuit Interrupter) and How Does it Work? Each year thousands of people get injured and hundreds of people die due to accidents associated with…
Read More » -
Solar Power
How to Determine the Suitable Size of Inverter for Home Appliances?
How Much Watts Inverter/UPS Do You Need for Home Appliances? Solved Example A power inverter is a device that converts DC supply to AC supply. Most household appliances are designed…
Read More » -
Electrical Wiring
How to Determine the Number of Circuit Breakers in a Panel Board?
How to Calculate the Number of Circuit Breakers for a Home Load Center and Distribution Board Based on the Load Calculation? In the USA and Canada, the common supply voltage…
Read More » -
Electrical Wiring
How to Size a Load Center, Panelboards and Distribution Board?
Sizing Main Panel, Load Center, Panelboards, Distribution Board & Consumer Unit According to NEC and IEC? Planning is the first and most critical priority for all electrical wiring projects. Proper…
Read More » -
Protection
MCCB (Molded Case Circuit Breaker) – Construction, Types & Working
What is MCCB (Molded Case)? Types, Construction, Operation & Applications Circuit breakers are electrical devices that offer protection against fault current. They use different medium to safely extinguish the arc…
Read More » -
Electrical Wiring
How to Wire a Garage Consumer Unit?
Wiring a Garage Consumer Unit with RCD & Connecting 1-Φ, 230V Load Points in it. What is a Garage Consumer Unit? A Garage Consumer is a type of consumer unit…
Read More » -
Electrical Wiring
How to Wire 1-Phase & 3-Phase Split Load Distribution Board?
Wiring a 230V/400V, 1-Φ & 3-Φ Split Load Distribution Board: UK & EU – IEC Split Load & Dual Split Load Distribution Boards The dual split load three phase distribution…
Read More »