Electrical Wiring
-
PLC
Automatic Reverse Forward Motor Control Using S7-1200 PLC
Control Scheme for Automatic FWD/REV Direction of Rotation of 3-Phase Motor Using Siemens PLC – S7-1200 Industrial automation has become an integral part of manufacturing processes. The use of Programmable…
Read More » -
Control
Automatic Sequential Operations of Motors – Power, Control, PLC & Wiring Circuits
How to Run Motors in Sequence? Power, Control, PLC & Wiring Diagrams A Sequential Motor Control Circuit is an electrical circuit designed to control the operation of motors in a…
Read More » -
Electrical Wiring
How to Control One Light Bulb From Two Different Locations?
2-Way & 3-Way Switching Connections – Electrical Wiring Diagrams What is Two Way & Three-Way Switching Circuits? Two-way switching or (three-way circuits in the US) connection is used to control…
Read More » -
Electrical Wiring
How to a Wire Double 3-Way Combination Switch Device?
Installation of Double Three-Way Switch Combo Device for Common & Separated Feed What is a Double 3-Way Combo Switch Device? A Three-Way combo switch device is actually the combination of…
Read More » -
Electrical Wiring
How to a Wire 3-Way Combination Switch and Grounded Outlet?
Installation of Three-Way Combo Device for Common and Separated Feed What is a 3-Way Combination Device? A Three-Way combo device with an outlet is actually the combination of a grounded…
Read More » -
Electrical Wiring
How to Wire Double Switch? 2-Gang, 1-Way Switch – IEC & NEC
Installation of Combination Double Switch (NEC) AKA 2-Gang, 1-Way Switch (IEC) for 120/240V & 230V AC What is Combination Double Switch (AKA 2-Gang, 1-Way Switch)? Double Switch (NEC) or 2-Gang,…
Read More » -
Electrical Wiring
How to Wire 4-Way Switch (NEC) or Intermediate Switch as 3-Way (IEC)?
How to Wire an Intermediate Switch as Three-Way Switching & Wiring Crossover Switch as Four-Way Switching – IEC & NEC What is 4-Way Switch and 3-Way Switch – NEC &…
Read More » -
Electrical Wiring
How to Wire Double Pole, Double Throw Switch? Wiring DPDT
How to Wire an DPDT Switch? Controlling 120V/240V & 230V Circuit using Double Pole, Double Throw Switches What is Double Pole, Double Throw (DPDT) Switch? DPDT stands for Double Pole,…
Read More » -
Electrical Wiring
How to Wire Double Pole, Single Throw Switch? Wiring DPST
How to Wire an DPST Switch? Controlling 120V/240V & 230V Circuit using Double Pole, Single Throw Switches What is Double Pole, Single Throw (DPST) Switch? DPST stands for Double Pole,…
Read More » -
Electrical Wiring
How to Wire Single Pole, Double Throw (SPDT) as 3-Way Switch?
Installation of SPDT – 3-Way Switch (NEC) AKA 2-Way Switch (IEC) for 120/240V & 230V AC – 3-Way & 2-Way Circuits What is SPDT Switch? SPDT (stands for Single Pole…
Read More »