How to Measure Resistivity of Earth Using Wenner Method?
Wenner 4-Point Method for Testing the Specific Resistance of Soil What is Wenner 4-Point Test? The Wenner Method (named after Dr. Frank Wenner of the US Bureau of Standards in…
Read More » -
Protection
How to Test the Earth Fault Loop Impedance – Various Methods
Testing and Measuring Earth Fault Loop Impedance using Different Methods What is Earth Fault Loop Impedance (EFL)? Earth fault loop impedance refers to the electrical resistance in the earth path…
Read More » -
Protection
How to Measure Ground Resistance? – Testing Earth Resistance
How to Measure the Earth – Ground Resistance using Different Methods? Grounding, also known as earthing, is a safety practice and technical technique that involves connecting electrical systems and equipment…
Read More » -
Measuring Instruments
What is Ground Resistance Tester – Working of Ground or Earth Tester
Earth – Ground Resistance Tester – Construction, Working and Applications Earth or ground resistance testers play a vital role in assessing the effectiveness of grounding and earthing systems by measuring…
Read More » -
Protection
Why is Copper Rod Used as Ground Rod in Grounding / Earthing System?
Why is Solid Copper Rod Preferred to use in Earthing / Grounding Instead of Iron, Steel etc.? While copper is a common choice for grounding rods, other materials like aluminum,…
Read More » -
Protection
What is Ground Rod and How to Install a Ground Electrode in Grounding System?
Ground Rod in Grounding System – Size, Role, Types, Installation and Applications What is a Ground Rod? A ground rod, also known as an earthing rod, grounding rod or ground…
Read More » -
Protection
Why is the Grounding Wire Bare and Not Insulated?
Why is Mostly Solid Bare Conductor Used for Grounding Instead of Insulated Wire? A ground wire, also known as a grounding wire or ground conductor, as the name implies, is…
Read More » -
Protection
Why are Salt and Charcoal Added in Earthing Pit for Grounding?
Why We Must Put Charcoal and Salt for Earthing and Grounding? For proper earthing and grounding, it is very important to maintain low resistance of grounding / earthing conductors by…
Read More » -
Protection
Difference Between Grounding, Earthing and Bonding
What is the Difference between Earthing, Grounding and Bonding? There is unusual confusion to understand the basic concept and main difference among grounding, earthing and bonding even some professionals interchanged…
Read More »