Charge Controller
-
Renewable Energy
How to Calculate the Right Size of Solar Charge Controller?
What is Solar Charge Controller? Types, Sizing and Selection of PWM & MPPT Charge Controllers Solar charge controllers are a vital part of any solar installation. They secure your battery…
Read More » -
Electrical Wiring
Calculation & Design of Solar Photovoltaic Modules & Array
Determining the Number of Cells in a Module, Measuring Module Parameters and Calculating the Short-Circuit Current, Open Circuit Voltage & V-I Characteristics of Solar Module & Array What is a…
Read More » -
Electrical Wiring
Series, Parallel & Series-Parallel Connection of Solar Panels
Series, Parallel and Series-Parallel Configuration of Photovoltaic Arrays What is a Solar Photovoltaic Array? A Solar Photovoltaic Module is available in a range of 3 WP to 300 WP. But…
Read More » -
Electrical Wiring
How to Wire Solar Panels in Series-Parallel Configuration?
Series-Parallel Connection of Solar Panels to the Battery and Inverter For small residential loads, using a series-parallel combination of solar panels is less common but still a possible wiring configuration.…
Read More » -
Electrical Wiring
How to Wire Batteries in Series-Parallel to a Solar Panel?
Series-Parallel Connection of Batteries to the PV Panel This is another possible wiring connection of series parallel combination of batteries connected to the solar panels. As we may connect the…
Read More » -
Electrical Wiring
How to Wire Batteries in Parallel to a Solar Panel and UPS?
Parallel Connection of Batteries to the PV Panel In our previous solar panel wiring installation tutorials, we showed how to wire solar panels and batteries in series, parallel and combination…
Read More » -
Electrical Wiring
How to Wire Batteries in Series to a Solar Panel and UPS?
Series Connection of Batteries to the PV Panel We know that solar panels and batteries can be wired either in series, parallel or combination of series-parallel connection depending on the…
Read More » -
Electrical Wiring
How to Wire Solar Panel to 12V DC Load and Battery?
Wiring PV Panel to Charge Controller, 12V Battery & 12VDC Load In this simple solar panel wiring tutorial, we will show how to connect a solar panel to the solar…
Read More » -
Electrical Wiring
How to Wire Solar Panel to 120-230V AC Load and Inverter?
Wiring PV Panel to UPS-Inverter, 12V Battery and 120-230V AC Load In this very basic solar panel wiring installation tutorial, we will show how to connect a solar panel to…
Read More » -
Electrical Wiring
How to Wire Solar Panels & Batteries in Series-Parallel Connection?
Wiring Batteries and Solar Panel in Series-Parallel Configuration You may think what is the purpose of this weird combination of series and parallel connection of both solar panels and batteries…
Read More »