230V
-
Protection
IEC and BS 7671 Requirements for Consumer Unit and Distribution Board
IEC-60364 and BS-7671 Guidelines for Garage Unit, Consumer Unit and Distribution Board The IEC (International Electrotechnical Commission) and BS 7671 (British Standard for Electrical Installations) both provide essential requirements for…
Read More » -
Power System
Why is the Standard Voltage in the US 120V/240V and 230V in the EU?
Why is the Standard Voltage in US homes 120V & 240V but 230V in the EU? Why Not Other Higher or Lower Levels of Voltage? Why Does the USA Use…
Read More » -
Power System
Why is the Standard Frequency 60 Hz in the US & 50 Hz in the EU?
Why is the Standard Frequency for Supply in the EU 50 Hz, But 60 Hz in the US? And Why Were Other Higher or Lower Frequencies Not Chosen? In the…
Read More » -
Power System
Advantages & Disadvantages of 50 Hz and 60 Hz Frequency Power Supply
Advantages and Disadvantages of 60 Hz (US) and 50 Hz (EU) Frequency We know that the frequency of the supply voltage in North American countries, including Canada and the US,…
Read More » -
Power System
Difference Between 50 Hz and 60 Hz Frequency System
What is the Difference Between 50-Hz and 60-Hz Frequency System? The electricity that we use in our homes is produced and supplied by huge generators inside the power generation stations.…
Read More » -
Protection
Which One is More Dangerous? 50Hz or 60Hz in 120V/230V & Why?
Which Frequency Level is Safer? 60Hz or 50Hz in 230V & 120V Circuits? Here is another silly question because there is no significant difference between 50Hz and 60Hz. It would…
Read More » -
Protection
Which One is More Dangerous? 120V or 230V and Why?
Which AC Voltage Level is Safer? 230V or 120V in Domestic and Residential Applications We all know that the domestic and residential voltage levels at the homes are 230V AC…
Read More » -
Electrical Wiring
How to Wire Double Switch? 2-Gang, 1-Way Switch – IEC & NEC
Installation of Combination Double Switch (NEC) AKA 2-Gang, 1-Way Switch (IEC) for 120/240V & 230V AC What is Combination Double Switch (AKA 2-Gang, 1-Way Switch)? Double Switch (NEC) or 2-Gang,…
Read More » -
Electrical Wiring
How to Wire 4-Way Switch (NEC) or Intermediate Switch as 3-Way (IEC)?
How to Wire an Intermediate Switch as Three-Way Switching & Wiring Crossover Switch as Four-Way Switching – IEC & NEC What is 4-Way Switch and 3-Way Switch – NEC &…
Read More » -
Electrical Wiring
How to Wire Double Pole, Double Throw Switch? Wiring DPDT
How to Wire an DPDT Switch? Controlling 120V/240V & 230V Circuit using Double Pole, Double Throw Switches What is Double Pole, Double Throw (DPDT) Switch? DPDT stands for Double Pole,…
Read More »