Troubleshooting
-
What Happens to the Battery with Reverse Polarity Wiring Connection
Charging & Discharging the Battery with Incorrect and Wrong Connection We know that a secondary battery (also known as an accumulator) is a device that converts the chemical energy into…
Read More » -
ABYC Cable & Wire Color Codes for Yacht, Boat & Marine Wiring
Marine & Boat Cable and Wire Color Codes What is a Marine Wire & Boat Cable? An insulated electrical wire and cable used in marine (boat, ship, yacht & vessels…
Read More » -
FACTS – Flexible AC Transmission System – Types of FACTS Controllers & Devices
Flexible Alternating Current Transmission System – FACTS Controllers & Devices What is FACTS and Related Devices? FACTS stands for Flexible Alternating Current Transmission System or simply Flexible AC Transmission System.…
Read More » -
Types of Electrical Drawings and Wiring Circuit Diagrams
Different Types of Electrical Wiring Circuit Diagrams and Drawings In Electrical and Electronics Engineering, we use different types of drawings or diagrams to represent a certain electrical system or circuit.…
Read More » -
Can We Use AC Circuit Breaker for DC Circuit & Vice Versa?
Why DC Circuit Breakers Can’t be Used in an AC Circuit and Vice Versa? Both AC and DC are electrical energies having the same heating effects for the same RMS…
Read More » -
Are The Batteries Connected in Series or Parallel?
Batteries Configuration. Series or Parallel? Basic Electrical Engineering Interview Question and Answers Series: Batteries configuration. Are these two batteries connected in series or parallel? and how to connect load to…
Read More » -
What is the Current in Ampere Meter?
Ampere Meter Basic Concept: What is the Current in Ammeter ? Basic Electrical Engineering Interview Question Series: An ammeter is connected in series with a 50 ohms and 100 ohms…
Read More » -
What is the Current in Ammeter Connected in Parallel?
If an Ammeter is Connected in Parallel with Load, What is the Deflection? Basic Electrical Engineering Interview Question Series: An Ampere meter is connected in parallel with the 100 ohms…
Read More » -
Will the Bulb Connected in This Strange Circuit Glow? And What is the Current in Ammeter?
Will the Bulb Glow Connected in this Strange Circuit? Also, What is the Ammeter Readings? Basic Electrical Engineering Interview Question Series: A bulb is connected in a strange circuit in…
Read More » -
What is the Current in Ammeter?
Ammeter Basic Concept: What is the Current in Ampere Meter ? Basic Electrical Engineering Interview Question Series: An Ampere meter is connected in series with the 100 ohms load. If…
Read More »