1-Phase Circuits
Single Phase AC Circuits
-
What is the Difference Between Neutral, Ground and Earth?
The Main difference between Neutral, Ground and Earth? To understand the difference between Neutral, Ground and Earth, we must first understand the purpose of these elements. Neutral Neutral is the return…
Read More » -
Star and Delta Connected Lighting Loads
Star and Delta Connected Lighting Loads – Electrical Wiring Installation Star (Y) Connected Lighting Load – Electrical Wiring A Star connected (Three Phase Four wires or 3-Phase, 4 wires) lighting system…
Read More » -
Single Phase & Three Phase Wiring Diagrams (1-Phase & 3-Phase Wiring)
Single Phase & Three Phase Wiring Diagrams (1-Phase & 3-Phase Wring) Single Phase Electrical Wiring Installation in Home according to NEC & IEC Three Phase Electrical Wiring Installation in Home…
Read More » -
Difference Between AC and DC Resistance – Which One is More?
Difference Between AC & DC Resistances & How to Calculate it? Resistance The property of a substance or material which oppose the flow of electricity through it is called resistance…
Read More » -
What is an Electric Circuit? Types of Circuits and Network
Electric Circuit, Network, Complex Circuits and other Types of Circuits What is an Electric Circuit? An electric circuit is a closed loop network which provides a return path for the…
Read More » -
How to Determine the Number of Nodes, Loops, Branches & Meshes in a Circuit?
What is Node, Branch, Loop and Mesh in an Electric Circuit, and How to Identify them? Understanding the fundamentals of electric circuits and networks is crucial for solving and analyzing…
Read More » -
Difference Between Linear and Nonlinear Circuits and Elements
What is the Difference Between Linear and Nonlinear Circuits Linear and nonlinear circuits are two different types of electrical systems. In this article, we are going to describe the key…
Read More » -
Three Phase Electrical Wiring Installation in Home – NEC & IEC
How to Wire 3-Phase Electrical Distribution Board & Consumer Unit in Home In our today electrical wiring installation tutorial, we will show how to wire and install a Three Phase…
Read More » -
How to Connect a Portable Generator to the Home Supply – 4 Methods
How to Wire a 1-P & 3-P Portable Generator to the Home Supply using Changeover & Without Changeover or Transfer Switch (ATS & MTS) for 230V/400V & 120V/240V We all…
Read More » -
How to Calculate the Suitable Capacitor Size in µ-Farads & kVAR for P.F Improvement
How to Find the Right Size Capacitor Bank Value in both kVAR and Microfarads for Power Factor Correction – 3 Methods As we got lots of emails and messages from…
Read More »