Power System
-
How to Convert Capacitor μ-Farads to kVAR and Vice Versa? – For P.F Correction
How to Convert Capacitor kVAR to μ-Farads & Vice Versa for Power Factor Improvement? Conversion of kVAR to μ-Farad & μ-Farad to kVAR The following simple calculation tutorial shows how…
Read More » -
Advantages of Power Factor Improvement and Correction
Advantages of Improved Power Factor Power factor improvement and correction refer to the process of increasing the power factor of an electrical system by reducing the reactive power consumption. This…
Read More » -
Sources and Causes of Low Power Factor
Causes and Sources of Poor Power Factor In an electrical power system, power factor is the ratio of the real power (kW) to the apparent power (kVA). A low power…
Read More » -
Power Factor Improvement Methods with their Advantages & Disadvantages
Different Methods Used for for Power Factor Correction The following devices and equipment are used for power factor improvement in an electrical system. Capacitor Banks: A bank of capacitors can…
Read More » -
Power Factor Library
Power Factor Library What is Power Factor (Cosθ) ? Cos fi or P.f Definitions & Formulas Advantages of Power factor improvement and Correction Disadvantages of Low Power Factor Causes of…
Read More » -
Power System Library
Power System Library Typical Electric Power System – Generation, Transmission & Distribution of Electricity Comparison between AC and DC Transmission System ( With their advantages and disadvantages) Active, Reactive, Apparent…
Read More » -
Overhead Power Lines
Overhead Power Lines Library Electrical Transmission Networks – EHV and HV Overhead Lines Corona Effect & Discharge in Transmission Lines & Power System Failures In Electrical Systems, Equipment & Materials…
Read More » -
Disadvantages of Low Power Factor
What are the Disadvantages of Low Power Factor (P.F)? Power factor plays an important role in AC circuits as we know that power dissipation in three phase circuits Power in a…
Read More » -
Active, Reactive, Apparent and Complex Power
What is Active, Reactive, Apparent and Complex Power? What is Active Power: (P) Active Power is the actual power which is really transferred to the load such as transformer, induction…
Read More » -
Power System MCQs with Explanatory Answers
Power System MCQs with Explanatory Answers (Generation, Transmission and Distribution MCQs with Explanatory Answers ) 1. Volume of The Conductor is inversely proportional to the ____________. Voltage (V) Half of…
Read More »