Motors
-
Speed Control of DC Motor – Voltage, Rheostatic & Flux Control Methods
Speed Control Methods of DC Motor – Voltage, Rheostatic & Flux Control of Series & Shunt DC Motors A DC motor is used to convert the direct current (DC) electrical…
Read More » -
Three-Phase Induction Motor – Construction, Working, Types & Applications
Three-Phase Induction Motor – Construction, Operation & Types of 3-Phase Induction Motors The motor is used to convert an electrical form of energy into mechanical form. According to the type…
Read More » -
Single-Phase Induction Motor – Construction, Working, Types & Applications
Single-Phase Induction Motor – Construction, Operation & Types of 1-Phase Induction Motors The single-phase motors are more preferred over a three-phase induction motor for domestic, commercial applications. Because form utility,…
Read More » -
DC Machine – Construction, Working, Types and Applications
Construction, Classification, and Applications of DC Machine According to the source of supply, electrical machines are classified into two types; AC machine and DC machine. For example, DC Motors, DC…
Read More » -
Direct Online Starter – DOL Starter Wiring Diagram for Motors
DOL Starter for Motors – Direct Online Starter Diagram, Working, Types & Applications The induction motor draws a huge amount of current at startup. This starting current can damage the…
Read More » -
Difference between AC Drives and DC Drives
Main Differences between AC and DC Drives What is a Drive and Electrical Drives A drive is an electrical or electronic device used to control the speed and motion of…
Read More » -
What is Motor Starter? Types of Motor Starters and Motor Starting Methods
Types of Motor Starters and Motor Starting Techniques What is a Motor Starter? A motor starter is an electrical device that is used to start & stop a motor safely.…
Read More » -
How to Replace a Ceiling Fan Capacitor – 3 Ways
How to Install and Connect a Capacitor in a Ceiling Fan? If you ever face a problem with the ceiling fan such as humming noise, slow speed, not running the…
Read More » -
Difference Between a Transformer and an Induction Motor
An Induction Motor is fundamentally a Transformer – What is the Difference? The induction motor is fundamentally a transformer in which the stator is the primary and the rotor is…
Read More » -
Electric Motors Symbols
Symbols of AC / DC, Single Phase & Three Phase Electric Motors A list of all electrical motors symbols in single image is given below as a reference at the…
Read More »