Electrical Wiring
Electrical Wiring Installation Tutorials
-
What is an RCBO (Residual Current Breaker with Overcurrent)?
Residual Current Breaker with Overcurrent (RCBO) – Construction, Types, Working and Applications What is An RCBO? An RCBO, or Residual Current Breaker with Overcurrent, is a type of electrical protection…
Read More » -
What is an RCD (Residual Current Device)? – RCB and RCCB
Residual Current Device or Residual Current Circuit Breaker – Construction, Working, Types, Rating and Applications What is an RCD? An RCD, which stands for Residual Current Device, is also known…
Read More » -
Why is Copper Rod Used as Ground Rod in Grounding / Earthing System?
Why is Solid Copper Rod Preferred to use in Earthing / Grounding Instead of Iron, Steel etc.? While copper is a common choice for grounding rods, other materials like aluminum,…
Read More » -
What is Ground Rod and How to Install a Ground Electrode in Grounding System?
Ground Rod in Grounding System – Size, Role, Types, Installation and Applications What is a Ground Rod? A ground rod, also known as an earthing rod, grounding rod or ground…
Read More » -
How to Wire Twin Timer for Repeated ON-Delay in Cycle Mode?
Wiring Digital Twin Timer in Repeated ON Delay Cycle Mode In our previous wiring tutorial, we discussed how to wire a one-shot timer using a twin timer for delay. In…
Read More » -
Wire Twin Timer in Repeat Cycle & One-Shot Mode for 120V/240V Motors?
How to Wire Twin Timer in Repeat Cycle and One-Shot Mode for 120V/240V Motors? A digital twin timer can be wired and configured for repeat cycle (ON-delay or OFF-delay) and…
Read More » -
How to Wire Twin Timer for 120V/240V Circuits – ON/OFF Delay
Wiring Digital Twin Timer for ON/OFF Delay Operations in 120 and 240V Circuits As the name suggests, a digital twin timer performs dual operations in a single circuit. It can…
Read More » -
How to Wire Multifunction ON/OFF Delay Timer for 120V/240V Motors?
How to Control 120V/240V Motor using Multifunction ON-OFF Delay Timer? In today’s step-by-step wiring tutorial, we will learn how to wire an OFF-delay and ON-delay timer for 120V and 240V…
Read More » -
How to Wire One-Shot Timer using Twin Timer For Delay?
Wiring Twin Timer for One-Shot Operation of Recirculation Pump What is a One-Shot Timer? As the name suggests, it performs a single operation per signal activation instead of repeated cycle…
Read More » -
How to Control 120V & 240V Water Heater using ST01 Timer and Contactors?
How to Wire ST01 Timer with Relay & Contactor for 120V/240V Water Heater? In today’s wiring tutorial, we will demonstrate how to wire and control a 120V and 240V water…
Read More »