How to Wire Single-Phase, 230V Consumer Unit with RCD? IEC, UK & EU
Wiring a 1-Φ, 230V Consumer Unit & Distribution Board with & without RCD: IEC, EU & UK What is a Consumer Unit? A consumer unit (CU) also known as panel…
Read More » -
How to Wire 277V & 480V, 1-Phase & 3-Phase, Commercial Main Service Panel?
Wiring a 480V & 277V, Single & Three Phase Main Breaker Box for Commercial Applications What is 277 & 480V Commercial Supply? 277V is a standard single phase voltage derived…
Read More » -
How to Wire 240V, 208V & 120V, 1 & 3-Phase, High Leg Delta Main Panel?
How to Wire High Leg Delta Main Panel for 120V, 208V & 240V, Single Phase & Three Phase Circuits? What is High Leg Delta? High Leg Delta (also known as…
Read More » -
How to Wire 120V & 208V – 1 & 3-Phase Main Panel? 3-Φ Load Center Wiring
Wiring Installation of Single Phase & Three Phase, 120V & 208V Circuits & Breakers in Main Service Panel In the USA, 208V single phase and three phase voltage is one…
Read More » -
How to Wire 120V & 240V Main Panel? Breaker Box Installation
Wiring Installation of Single Phase 120V & 240V Circuits & Breakers in Main Service Panel In the USA and Canada (following NEC and CNC), the distribution transformer has 4.5kV-7.2kV at…
Read More » -
AWG/SWG to mm/mm2, inch/inch2 & kcmil Calculator & Conversion
AWG and SWG Size Conversion Calculator with Formula, Chart & Table Standard Wire Gauge “SWG” Calculator The following American Wire Gauge “AWG” and Standard Wire Gauge “SWG” calculators will calculate…
Read More » -
Standard Wire Gauge “SWG” Calculator – SWG Size Chart & Table
SWG “Standard Wire Gauge” Size Calculator & Cable Properties Table & Chart Standard Wire Gauge “SWG” Calculator The following Standard Wire Gauge (SWG) calculator will calculate the diameter in inches,…
Read More » -
American Wire Gauge “AWG” Calculator – AWG Size Chart & Table
AWG “American Wire Gauge” Size Calculator & Cable Properties Table & Chart American Wire Gauge “AWG” Calculator The following American Wire Gauge (AWG) calculator will calculate the diameter in mm,…
Read More » -
Series, Parallel & Series-Parallel Connection of Solar Panels
Series, Parallel and Series-Parallel Configuration of Photovoltaic Arrays What is a Solar Photovoltaic Array? A Solar Photovoltaic Module is available in a range of 3 WP to 300 WP. But…
Read More » -
How to Wire Solar Panels in Series-Parallel Configuration?
Series-Parallel Connection of Solar Panels to the Battery and Inverter For small residential loads, using a series-parallel combination of solar panels is less common but still a possible wiring configuration.…
Read More »