Electrical Wiring
Electrical Wiring Installation Tutorials
-
How to Wire 1-Phase & 3-Phase Split Load Distribution Board?
Wiring a 230V/400V, 1-Φ & 3-Φ Split Load Distribution Board: UK & EU – IEC Split Load & Dual Split Load Distribution Boards The dual split load three phase distribution…
Read More » -
How to Wire a Three Phase, 400V Distribution Board? IEC & UK
Wiring a 3-Phase, 400V Distribution Board: UK & EU – IEC Three Phase Distribution Board A distribution board is the combination of protective devices such as Main switch, MCB, MCCB, RCD,…
Read More » -
How to Wire Combo of 3 & 1-Φ, 400V/230V Distribution Board?
Wiring a Combination of 1-Phase & 3-Phase , 230V/400V Distribution Board: IEC-EU & UK What is a Distribution Board? A distribution board (also known as electric panel, breaker panel, panelboard, main breaker-box or main…
Read More » -
How to Wire 1-Phase Split Load Consumer Unit? – RCD+RCBO
Wiring a Single-Phase Split Load Consumer Unit & Distribution Board : IEC, EU & UK What is a Split Load Consumer Unit? A Split Load Consumer Unit is also known…
Read More » -
How to Wire 230V Dual Split Load Consumer Unit? – RCD+MCB
Wiring a 1-Φ, 230V Dual Split Load Consumer Unit & Distribution Board : IEC, EU & UK What is a Dual Split Load Consumer Unit? Dual split load consumer unit…
Read More » -
How to Wire Single-Phase, 230V Consumer Unit with RCD? IEC, UK & EU
Wiring a 1-Φ, 230V Consumer Unit & Distribution Board with & without RCD: IEC, EU & UK What is a Consumer Unit? A consumer unit (CU) also known as panel…
Read More » -
How to Wire 277V & 480V, 1-Phase & 3-Phase, Commercial Main Service Panel?
Wiring a 480V & 277V, Single & Three Phase Main Breaker Box for Commercial Applications What is 277 & 480V Commercial Supply? 277V is a standard single phase voltage derived…
Read More » -
How to Wire 240V, 208V & 120V, 1 & 3-Phase, High Leg Delta Main Panel?
How to Wire High Leg Delta Main Panel for 120V, 208V & 240V, Single Phase & Three Phase Circuits? What is High Leg Delta? High Leg Delta (also known as…
Read More » -
How to Wire 120V & 208V – 1 & 3-Phase Main Panel? 3-Φ Load Center Wiring
Wiring Installation of Single Phase & Three Phase, 120V & 208V Circuits & Breakers in Main Service Panel In the USA, 208V single phase and three phase voltage is one…
Read More » -
How to Wire 120V & 240V Main Panel? Breaker Box Installation
Wiring Installation of Single Phase 120V & 240V Circuits & Breakers in Main Service Panel In the USA and Canada (following NEC and CNC), the distribution transformer has 4.5kV-7.2kV at…
Read More »