Formulas – Equations
Electrical Engineering Formulas and Equations
-
800+ Electrical & Electronic Abbreviations with Full Forms. A-Z
Electrical and Electronics Engineering Abbreviations with Full Forms Below is the list of 800+ short form or abbreviation with full form used in electrical and electronic engineering. All the abreavtion…
Read More » -
Short Circuit Currents And Symmetrical Components
Short Circuit Currents And Symmetrical Components (Manuel Bolotinha) Short Circuit Faults and Currents Short-circuits can occur phase-to-phase and phase-to-earth, mainly due to: Dielectric breakdown of insulating materials (ageing, severe overheating…
Read More » -
Lighting Design Calculation in a Building – Step by Step
How to do Lighting Design Calculation in a Building – Electrical Wiring Installation In professional field proper lighting design is very important because an under lighting arrangement will decrease the…
Read More » -
Kirchhoff’s Current & Voltage Law (KCL & KVL) | Solved Example
KCL & KVL – Kirchhoff’s First & Second Laws with Solved Example A German Physicist “Robert Kirchhoff” introduced two important electrical laws in 1847 by which, we can easily find…
Read More » -
SUPERNODE Circuit Analysis | Step by Step with Solved Example
Supernode Analysis – Statement, Formula and Step by Step Solved Example What is Supernode Analysis? Today, we will try to answer the common question of why we use Supernode circuit analysis while…
Read More » -
SUPERMESH Circuit Analysis | Step by Step with Solved Example
Supermesh Analysis – Statement, Formula, Solved Examples What is Supermesh Analysis? Supermesh or Supermesh Analysis is a better technique instead of using Mesh analysis to analyze such a complex electric circuit or network, where two…
Read More » -
Cramer’s Rule Calculator – 2 and 3 Equations System
Cramer’s Rule & Calculator for Linear Circuit Analysis | Step by Step with Solved Examples Today, we are going to share another simple but powerful circuit analysis technique which is…
Read More » -
What is Voltage Drop? Advanced Voltage Drop Calculator with Solved Examples
Advanced Voltage Drop Calculator with Solved Examples & Formulas in IEC and IEC What is Voltage Drop? Voltage drop refers to the reduction in voltage as electric current flows through…
Read More » -
Delta Connection (Δ): 3 Phase Power, Voltage & Current Values
Three Phase Delta Connection: Line, Phase Current, Voltages & Power in Δ Configuration What is Delta Connection (Δ)? Delta or Mesh Connection (Δ) System is also known as Three Phase…
Read More »