Questions – Answers
Electrical and Electronics Engineering Interview Questions and Answers
-
Why You Should Never Buy or Use Male-to-Male Extension Cords
Why You Should Immediately Stop Using and Never Consider Male-to-Male Extension Cords What is a Male-to-Male Extension Cord? A male-to-male extension cord is a cable with male (pronged) plugs on…
Read More » -
Why is the Neutral Wire Size Smaller than the Phase Wire?
Why is the Size of the Neutral Conductor Smaller than the Line Conductor in a Polyphase System? In a three-phase (poly-phase) system, the Neutral wire may sometimes be smaller than…
Read More » -
Why is the Ground Wire Size Smaller than the Hot Wire?
Why is the Size of the Ground Conductor Smaller than the Line Conductor? The ground wire does not always have to be the same size as the power (phase or…
Read More » -
Appliances You Should Never Plug Into an Extension Cord
List of Electrical Appliances You Should Never Plug Into an Extension Cord What is an Extension Cord? An extension cord is a flexible, insulated cable with a plug on one…
Read More » -
Why Do We Need a GFCI & How Does it Protect During Faults?
Why Do We Need a GFCI Breaker and How Does it Protect During Ground Faults? A Ground Fault Circuit Interrupter (GFCI) is designed to protect circuits by detecting electrical faults…
Read More » -
How Does a Standard Breaker Respond to Electrical Fault?
How Does an Ordinary Circuit Breaker Operates During Short Circuit, Overload & Ground Faults? When a standard circuit breaker detects a fault, such as an overload or short circuit, it…
Read More » -
Why Doesn’t a Standard Breaker Protract Against Ground Faults?
Why Does a Standard Breaker Pose a Shock Hazard with a Broken Neutral? A broken neutral in a circuit with a standard breaker can pose a shock hazard because the…
Read More » -
How Do GFCI and Standard Breakers Respond to Ground Faults?
How Does a GFCI Breaker Protect Us in Case of a Fault, Compared to Standard Breakers? An ordinary circuit breaker in the main panel for household appliances protects only in…
Read More » -
What Happens if the Neutral is Lost in the Main or Subpanel?
What Will Happen When the Neutral is Broken in the Main Panel or Subpanel? The neutral wire provides a return path for current back to the power source, completing the…
Read More » -
Why Must Neutral and Ground Wires Be Bonded in the Main Panel?
Why Do Neutral and Ground Conductors Need to Be Bonded in the Main Panel? According to NEC Article 250, both the neutral and ground wires must be connected only in…
Read More »