Electrical Machines
-
Difference Between Voltage Stabilizer and Voltage Regulator (AVR)
Difference Between Automatic Voltage Regulator (AVR) and Voltage Stabilizer Both voltage stabilizers and voltage regulators are used to control voltage levels. Voltage stabilizer is more focused on maintaining a stable…
Read More » -
Difference Between Servo Motor and Stepper Motor
What is the Main Difference Between Servo Motor and Stepper Motor? The Servo motor and stepper motor are both two different types of motor used for positioning. However, they are…
Read More » -
Difference Between Squirrel Cage and Slip Ring (Wound) Rotor
Difference Between Squirrel Cage Rotor & Wound Rotor (Slip Ring) Motors Among the different types of electric motors, squirrel cage and wound rotor motors are widely used. Both motor types…
Read More » -
Induction Generator or Asynchronous Generator: Construction & Working
Synchronous Generator or Induction Generator – Working, Types, Characteristics, Advantages and Applications Electricity is a form of energy that we use in almost every aspect of our life and we…
Read More » -
Why is a Capacitor Needed for a Single-Phase Motor?
Why is a Single-Phase Motor Not Self-Starting? Necessity of Capacitors in 1-Phase Motors A capacitor is required for a single-phase motor to provide the necessary phase shift to start the…
Read More » -
Why Do DC Motors Have Higher Starting Torque than AC Motors?
Why is the Starting Torque of a DC Motor Greater Than That of an AC Motor? DC (direct current) motors generally have higher starting torque compared to AC (alternating current)…
Read More » -
Betavolt Developed a Nuclear Battery with a 50-Year Lifespan
A Chinese Startup Unveiled a Nuclear battery (BV100) that Operates without Charging for 50 Years The company Betavolt in Beijing has announced the development of a battery capable of operating…
Read More » -
What Do the 5P10 and 5P20 Mean in a Current Transformer?
What Do the 5P20 and 5P10 Accuracy Classes Mean in Current Transformers? For a current transformer (CT), different accuracy classes, such as 5P10, 5P20, or 10P10, are chosen based on…
Read More » -
Wire Twin Timer in Repeat Cycle & One-Shot Mode for 120V/240V Motors?
How to Wire Twin Timer in Repeat Cycle and One-Shot Mode for 120V/240V Motors? A digital twin timer can be wired and configured for repeat cycle (ON-delay or OFF-delay) and…
Read More » -
How to Wire Multifunction ON/OFF Delay Timer for 120V/240V Motors?
How to Control 120V/240V Motor using Multifunction ON-OFF Delay Timer? In today’s step-by-step wiring tutorial, we will learn how to wire an OFF-delay and ON-delay timer for 120V and 240V…
Read More »