Why is a Capacitor Needed for a Single-Phase Motor?
Why is a Single-Phase Motor Not Self-Starting? Necessity of Capacitors in 1-Phase Motors A capacitor is required for a single-phase motor to provide the necessary phase shift to start the…
Read More » -
Why Do DC Motors Have Higher Starting Torque than AC Motors?
Why is the Starting Torque of a DC Motor Greater Than That of an AC Motor? DC (direct current) motors generally have higher starting torque compared to AC (alternating current)…
Read More » -
Wire Twin Timer in Repeat Cycle & One-Shot Mode for 120V/240V Motors?
How to Wire Twin Timer in Repeat Cycle and One-Shot Mode for 120V/240V Motors? A digital twin timer can be wired and configured for repeat cycle (ON-delay or OFF-delay) and…
Read More » -
How to Wire Multifunction ON/OFF Delay Timer for 120V/240V Motors?
How to Control 120V/240V Motor using Multifunction ON-OFF Delay Timer? In today’s step-by-step wiring tutorial, we will learn how to wire an OFF-delay and ON-delay timer for 120V and 240V…
Read More » -
How to Wire One-Shot Timer using Twin Timer For Delay?
Wiring Twin Timer for One-Shot Operation of Recirculation Pump What is a One-Shot Timer? As the name suggests, it performs a single operation per signal activation instead of repeated cycle…
Read More » -
How to Reverse Operation of Photo Eye for Motor using Relay?
How to Reverse the Operation of a Photo Eye Using a Relay, So the Motor Turns on During the Day Instead of at Night? Suppose we have a setup where…
Read More » -
How to Wire ST01 Timer with Relay & Contactor for 120V/240V Motors?
How to Control 120V & 240V Pump Motor using ST01 Timer, Relay and Contactors? As a versatile component, the ST01 timer can be used to control the sequential operations of…
Read More » -
How to Toggle between Two Heat Pumps using 240V Twin Timer?
Wiring Circuit Diagram to Operate One Heat Pump at a Time Using Timer The following wiring circuit ensures that both heat pumps do not run simultaneously. In other words, only…
Read More » -
How to Control a Single-Phase Motor from Multiple Locations?
Controlling the ON-OFF Operation of a 1-Phase Motor from Multiple Places using Contactor and Pushbuttons In large industrial and commercial premises, there are scenarios where we need to control a…
Read More » -
3-Phase Automatic Changeover (ATS) using Contactors and Timer
Automatic Changeover Switch (ATS) Connection using Contactors, Timer And Relay for 3-Phase Load Automatic changeover switches play a crucial role in ensuring uninterrupted power supply in various industrial, commercial and…
Read More »