Control
-
How to Calculate the Suitable Capacitor Size in µ-Farads & kVAR for P.F Improvement
How to Find the Right Size Capacitor Bank Value in both kVAR and Microfarads for Power Factor Correction – 3 Methods As we got lots of emails and messages from…
Read More » -
Controlling Library
Electrical Control Design & Installation of Control & Monitoring Systems in Electrical Engineering MV & HV Cable Termination to Equipment & Joints Personal Protective Equipment (PPE) for Electrical Works HV…
Read More » -
Wiring of the Distribution Board (Single Phase Supply From Utility Pole & Energy Meter to the Consumer Unit)
Electrical Wiring Installation of the Distribution Board (Single Phase Home Supply from Utility Pole & Energy Meter to the Consumer Unit) How to Wire a Distribution Board? Distribution Board aslo…
Read More » -
Wiring of the Distribution Board with RCD (Residual Current Devices) – Single Phase Home Supply
Electrical Wiring Installation of the Distribution Board with RCD (Single Phase Home Supply from Utility Pole & Energy Meter to the Consumer Unit) What is Distribution Board? Distribution board is…
Read More » -
Automatic Street Light Control Circuit using LDR & Transistor BC 547
Basic Electronic Project – Automatic Street Light Control Circuit Following is yet another simple Electrical/Electronics project for automatic street light control systems especially for students, newbies and hobbyists. Features: It…
Read More » -
Manual & Auto UPS / Inverter Wiring Diagram with Changeover Switch
How to do Manual & Auto UPS / Inverter Wiring with Changeover / ATS Switch In our previous UPS / Inverter wiring diagrams & connections for home, we show that how…
Read More » -
Automatic UPS Wiring for Partial Load – The rest Depends on Main Power
Automatic UPS / Inverter Wiring Diagram in Case of some items depends on UPS and the rest on Main or Generator Power Suppose you have two lighting bulbs, one ceiling…
Read More » -
How to Connect Automatic UPS / Inverter to the Home Supply System?
Automatic Inverter / UPS System Connection & Wiring Circuit Diagram Introduction to Automatic Inverter / UPS Wiring Power failure and emergency breakdown may happen any time due to short circuit, damage…
Read More » -
What is Intermediate Switch (3-Way in IEC) A.K.A 4-Way Switch in NEC?
4-Way Switch or Intermediate Switch (3-Way) – its Construction, Operation & Applications What is an Intermediate Switch? 4-Way switch in NEC (also known as 3-way or intermediate switch in IEC…
Read More »