Control
-
Two-Speed, One-Direction, 3-Phase Motor Power & Control Diagrams
How to Control a Dual/Tap-Wound 3-Phase Motor for 2-Speed and 1-Direction using Dahlander Connection? Three-phase motors are widely used in industrial applications due to their efficiency and robustness. Often, there’s…
Read More » -
Two-Speed, Two-Directions, 3-Phase Motor Power & Control Diagrams
How to Control a 3-Phase Motor for 2-Speed and 2-Directions using Dahlander Connection? The control of two-speed, two-direction three-phase motors plays a critical role in various industrial applications that require…
Read More » -
Reverse-Forward Star/Delta Starter for Three Phase Motor using Timer
Reverse and Forward Star / Delta (Y-Δ) Starter for Three Phase Motor using Timer Three-phase induction motors are widely used in industrial applications due to their efficiency and robustness. To…
Read More » -
Batteries Wiring Connections and Diagrams
Batteries Wiring Connections and Diagrams Series, Parallel and Series-Parallel Connection of Batteries How much Watts Solar Panel We need for our Home Electrical appliances? How To Wire Two 24V Solar…
Read More » -
Solar Panel Wiring Diagram and Installation Tutorials
Photovoltaic Solar Panel, Module String & Arrays Wiring & Installation Diagrams Solar Panel Wiring and Installation Diagrams Different Types of Solar Panel and Which one is the best PV Panel?…
Read More » -
UPS / Inverter Wiring Diagrams & Connection
UPS & Inverter Wiring Diagrams & Connection How to Design and Install a Solar PV System with Inverter? Solved Example How to Connect Automatic UPS / Inverter to the Home…
Read More » -
Three-Speed, One-Directions, 3-Phase Motor (Multispeed) – Power & Control
How to Control a 3-Phase Motor for 3-Speed and 1-Direction using Dahlander Connection? In applications where multi-speed control and one-direction rotation are needed, a specialized configuration utilizing both Dahlander connection…
Read More » -
Primary and Secondary or Backup protection in a Power System
Primary Protection Below is the power system protection scheme which is designed to protect the power system parts and components. As shown in below fig, each line associated with over current…
Read More » -
Three Phase Electrical Wiring Installation in Home – NEC & IEC
How to Wire 3-Phase Electrical Distribution Board & Consumer Unit in Home In our today electrical wiring installation tutorial, we will show how to wire and install a Three Phase…
Read More » -
How to Connect a Portable Generator to the Home Supply – 4 Methods
How to Wire a 1-P & 3-P Portable Generator to the Home Supply using Changeover & Without Changeover or Transfer Switch (ATS & MTS) for 230V/400V & 120V/240V We all…
Read More »