Capacitors
-
Why are Capacitors Connected in Series in Power Lines?
Why are Capacitors Connected in Series with Power Transmission Lines? While capacitors are often associated with shunt applications for power factor correction, series capacitors are widely used in transmission lines…
Read More » -
Why is a Capacitor Bank Connected in Parallel and Not in Series for P.F?
Why is a Capacitor Bank Connected in Parallel and Not in Series for Power Factor Correction? Capacitor banks are used to improve power factor and voltage regulation in electrical systems.…
Read More » -
Why is a Capacitor Needed for a Single-Phase Motor?
Why is a Single-Phase Motor Not Self-Starting? Necessity of Capacitors in 1-Phase Motors A capacitor is required for a single-phase motor to provide the necessary phase shift to start the…
Read More » -
Which One is More Dangerous? 50Hz or 60Hz in 120V/230V & Why?
Which Frequency Level is Safer? 60Hz or 50Hz in 230V & 120V Circuits? Here is another silly question because there is no significant difference between 50Hz and 60Hz. It would…
Read More » -
Capacitor Color Codes – How To Read Capacitor Value? Calculator
How to know the Value of Capacitance of a Capacitor using Standard & Color Codes – Calculator & Examples Same like the resistor color codes, there are special indications like…
Read More » -
How to Measure Capacitance using a Multimeter?
Measurement of Capacitance with a Digital Multimeter To accurately measure the capacitance of a capacitor, you require expensive instruments such as an LCR meter which can measure Inductance (L), Capacitance…
Read More » -
Parallel Capacitors Calculator
Capacitance of Parallel Connected Capacitors Calculator Formula & Equations for Parallel Capacitors Calculator Finding Total Resistance (RT) of series connected resistors network when R1 and R2 are given; CT = C1 + C2 Finding R1 when RT and R2 Given;…
Read More » -
Capacitor Bank in kVAR & µF Calculator for Power Factor Correction
How to Calculate the Capacitor Bank in kVAR & Microfarad for Power Factor Improvement? Calculator & Example Capacitor Bank Calculator The following Power factor improvement calculator will calculate the required…
Read More » -
Power Factor Correction Calculator – How to Find P.F Capacitor in µF & kVAR?
How to Calculate Capacitor in kVAR & µF for Power Factor Improvement? Calculator & Example Power Factor Calculator The following P.F calculator will calculate the existing or current power factor,…
Read More » -
μ-Farad to kVAR Calculator – How to Convert Farads to kVAR?
How to Convert Farad & Microfarad to kVAR? Calculator and Examples Microfarad to kVAR Calculator The following microfarad to kVAR conversion calculator will convert the capacitance of a capacitor “C”…
Read More »