Basic Concepts
-
Main Difference Between Clipper and Clamper Circuit
What is the Difference Between Clipper and Clamper Circuit? Clipper and clamper circuits are electronic circuits used for the modification of AC signals. The clipper circuit can clip a portion…
Read More » -
Difference Between Current Transformer & Potential Transformer
What is the Difference between Current Transformer and Potential or Voltage Transformer? The voltage and current used for electrical power transmission over long distances is very high. Measurement of such…
Read More » -
How to Find the Number of Lights on a Single Circuit Breaker?
How Many Lights Can You Put on a Single Circuit Breaker? – NEC & IEC Another basic query about the lighting points and fixtures on sub circuits and breakers we…
Read More » -
How to Find the Number of Outlets on a Single Circuit Breaker?
How Many Outlets Can You Put on a Single Circuit Breaker? – NEC & IEC The most frequently asked and searched question from home owners and DIY dudes is what…
Read More » -
How to Determine the Number of Circuit Breakers in a Panel Board?
How to Calculate the Number of Circuit Breakers for a Home Load Center and Distribution Board Based on the Load Calculation? In the USA and Canada, the common supply voltage…
Read More » -
How to Size a Load Center, Panelboards and Distribution Board?
Sizing Main Panel, Load Center, Panelboards, Distribution Board & Consumer Unit According to NEC and IEC? Planning is the first and most critical priority for all electrical wiring projects. Proper…
Read More » -
What is Multimeter? Working of Analog and Digital Multimeters
What is Multimeter? Types, Functions Working and Applications Electrical and electronics engineering students, engineers and technicians use various kinds of measurement devices to check various electrical quantities in a circuit…
Read More » -
Voltage Divider Rule (VDR) – Solved Examples for R, L and C Circuits
Voltage Division “VDR” for for Resistive, Inductive and Capacitive Circuits What is Voltage Divider Rule? In a circuit, when a number of elements are connected in series, input voltage divides…
Read More » -
Current Divider Rule (CDR) – Solved Examples for AC and DC Circuits
Current Division “CDR” for for Resistive, Inductive and Capacitive Circuits What is Current Divider Rule (CDR)? When a number of elements are connected in parallel, the current divides into a…
Read More » -
Compensation Theorem – Proof, Explanation and Solved Examples
Proof, Explanation, Experiment and Solved Examples of Compensation Theorem for Circuit Analysis Compensation Theorem Sime times in network theory, it is important to know or study the effect of change…
Read More »