Ohm’s Law Calculator – P, I, V, R Calculator

Ohm’s Law Calculator – Power, Current, Voltage & Resistance Calculator

Below are the four Electrical calculators based on Ohm’s Law with Electrical Formulas and Equations of Power, Current, Voltage and Resistance in AC and DC Single phase & Three Phase circuit.

Enter the known values and select a conversion from the buttons below and click on Calculate. result will display the desire values which you want to calculate.

Power Calculator

Calculate Power (W) in Watts using Ohm’s Law:
Enter any two values of: V, I, and R
V: I: R:
      
Watts (W):      

Electrical Power Formulas

Electrical Power formulas in DC Circuits

  • P = VxI
  • P = I2R
  • P = V2/R

Electrical Power formulas in Single Phase AC Circuits

  • P = VxI Cosθ
  • P = I2 x R Cosθ
  • P = (V2/R) Cosθ

Electrical Power formulas in Three Phase AC Circuits

  • P =√3 x VLxIL Cosθ
  • P =3 x VPxIP Cosθ
  • P =3 I2 x R Cosθ
  • P =3 (V2/R) x R Cosθ

Where

  • I = Current in Amperes (A)
  • V = Voltage in Volts (V)
  • P = Power in Watts (W)
  • R = Resistance in Ohm (Ω)

Related Post: Power, Voltage, Current and Resistance Calculator

Current Calculator

Calculate Current (I) in Amperes using Ohm’s Law:
Enter any two values of: V, W, and R
V: W: R:
3-Phase
      
Amperes (A):      

Electrical Current Formulas

Electrical Current Formulas in DC Circuit

  • I=V/R
  • I = P/V
  • I = √P/R

Electrical Current Formulas in Single Phase AC Circuit

  • I = P / (V x Cosθ)
  • I = (V/Z)…Where Z = impedance = Resistance of AC Circuits

Electrical Current Formulas in Three Phase AC Circuit

I = P / √3xVxCosθ

Where

  • I = Current in Amperes (A)
  • V = Voltage in Volts (V)
  • P = Power in Watts (W)
  • R = Resistance in Ohm (Ω)

Related Calculator: RMS Voltage Calculator – From Average Value, Peak & Peak to Peak Value

Voltage Calculator

Calculate Voltage (V) in Volts using Ohm’s Law:
Enter any two values of: W, I, and R
W: I: R:
      
Volts (V):      

Voltage or Electrical Potential Formulas

Electrical Potential or Voltage Formula in DC Circuits

  • V = I x R
  • V = P / I
  • V = √ (P x R)

Voltage or Electrical Potential Formulas in Single Phase AC Circuits

  • V = P/(IxCosθ)
  • V = I / Z… Where Z = impedance = Resistance of AC Circuits

Where

  • I = Current in Amperes (A)
  • V = Voltage in Volts (V)
  • P = Power in Watts(W)
  • P = Power in Watts(W)
  • R = Resistance in Ohm (Ω)

Related Calculator: Standard Resistor Closest Value Calculator

Resistance Calculator

Calculate Resistance (R) in Ohms (Ω) using Ohm’s Law:
Enter any two values of: V, I, and W
V: I: W:
      
R (Ohms = Ω):      

Electrical Resistance Formulas

  • R = V/I
  • R = P/I2
  • R = V2/P

Where

  • I = Current in Amperes (A)
  • V = Voltage in Volts (V)
  • P = Power in Watts (W)
  • R = Resistance in Ohm (Ω)

Ohm's Law Calculator - P, I, V, R Calculator with Formulas & Equations
Related Electrical Engineering Calculators

Electrical Technology

All about Electrical and Electronic Engineering & Technology. Join us on WhatsApp at Electrical Technology Official Channel, to receive the latest content, articles, and updates. You can also like and follow our social media networks below, or subscribe with your email to receive premium engineering articles in your mailbox.