How to Wire a UK 3-Pin Socket Outlet? Wiring a BS1363 Socket

Wiring a 1-Gang, BS1363, 3-Pin Switched Socket Outlet Safely and Correctly

3-Pin Socket Outlet

A 3-pin socket outlet, also known as a UK socket outlet, Type G outlet, or BS1363 socket outlet according to IEC standards, consists of three pins: Live “L,” Neutral “N,” and Earth “E.” It is available in multiple varieties, including 1-gang, 2-gang, switched, and switched with a neon bulb. Wiring diagrams for each type will be provided in upcoming posts based on system needs.

The basic BS-1363 3-pin socket (wall outlet) is commonly used in the UK, IEC, and other countries following the old UK codes or IEC standards, such as UAE, KSA, Malaysia, Singapore, Cyprus, Hong Kong, India, Pakistan, Bangladesh, Malta, and so on. This is because it offers comprehensive protective features.

Click image to enlarge

Wiring a BS 1363, 1-Gang, 3-Pin Socket Outlet

 

Related Posts:

Safety Features of BS1363 Socket

The 3-Pin BS-1363 socket outlet has the following protective features.

In the following tutorial, we will show how to wire and install a new three pin socket outlet or upgrade an outdated socket (already installed).

In this Switched 1, gang, 3-Pin socket, the switch is used to control the ON/OFF operation of the socket outlet as well as connected appliances. The built-in neon bulb (in the switch) indicates the ON/OFF position of the switch, plug and socket. For example, if the neon light is glowing, it means the switch is ON and the circuit is operating. If the light is not glowing, it indicates the switch is OFF and the plug, socket and appliance is disconnected from the main supply.

Click image to enlarge

Internal Wiring of BS1363, 3-Pin Socket Outlet

Related Posts:

Tools Required

The following basic tools are needed while wiring a 3-pin socket outlet.

Wiring a BS1363, 3-Pin Socket

Follow the following simple steps to wire a BS-1363 switched socket wall outlet.

Click image to enlargeHow to Wire a UK 3-Pin Socket Outlet

 

Remember:

Related Posts:

IEC & UK Wiring Color Codes:

We have used the following IEC wiring color codes for 230V single phase  supply voltage applicable in the UK and EU. The United Kingdom was using their own wiring color codes prior April, 2004 while some countries are still following the same old UK wiring color code. The United Kingdom is following IEC wiring color codes now.

IEC Wiring Color Codes for 230V, 1-Phase, 3-Wire System

The Old UK wiring color codes for single phase wiring are as follow.

230V Single Phase

Related Posts:

Instruction & Safety Precautions

Related Wiring Installation Tutorials:

Exit mobile version