Tunnel Wiring Circuit Diagram for Light Control using Switches

Tunnel Wiring Circuit Diagram – Working and Operation

Tunnel wiring circuit is used in open ended corridors and short tunnels like structures. In tunnel wring circuit diagram, we have used SPDT (two-way) switches to control the lighting points in tunnels and corridors. The tunnel circuit control the lamps in four ways as follow.

During normal light in the day i.e. from 7AM to 6PM, only the middle one bulb will glow and the first and last one will turned OFF. At night, the first and last one will glow while the middle one will OFF. During high traffic, all the three bulbs will turn ON. During maintenance or special operations, the circuit will work like godown circuit i.e. one by one lamp will turn ON in the sequence.

Keep in mind that the same operation may be achieved by some automation and electronics circuits while we are using only switches for this purpose in the following tutorial.

Tunnel Wiring Circuit for Light Control

Tunnel Wiring Circuit for Light Control using Switches

Requirements:

Component Rating Quantity
MCB 120V or 230V, 5A 1
Two – Way Switch SPDT,  5A 4
Light Bulb 40W 3
Wire Size 1.2mm PVC 2

Procedure:

Related Wiring Tutorial: Hotel Wiring Circuit – Bell Indicator Circuit for Hotelling

Working:

The tunnel circuit for lighting control is working in the following sequences:

First two switches are at down position while the 3rd and 4th are at up position. This way, the middle one i.e. 2nd bulb is turned ON and glowing while the other two bulbs are OFF as normal light do their job at outer and entrance of the short tunnel which leads to save energy.

First and last switches are at up while the second and third switches are at down position. This way, the first and last bulbs are turned ON during night and normal traffic.

All the bulbs are ON during high traffic at night in the tunnel. The first and third switches are at up and second and fourth switches are down position. This can also be done while switch 1 and 3 at down and switch 2 and 4 at up position i.e. reverse positions of both switches.

All the lamps can be turned off while all the switches are at UP or Down positions.

During maintenance operations, the tunnel circuit can be operate like a godown circuit where lamps can be turn ON and OFF in a sequence which is a better option in case of energy conservation.

The following table shows the working of a tunnel wiring circuit.

SPDT Switches Position Bulb ONN/OFF
S1, S2, S3, S4 = Up All Bulbs OFF
S1, S2, S3, S4 = Down All Bulbs OFF
S1, S2 = Down – S3, S4 = Up Bulb 2 ON
S1, S4 = Up – S2, S3 = Down Bulb 1 & 3 ON
S1, S3 = Up – S2, S4 = Down All bulbs ON
S1, S3 = Down – S2, S4 = Up All bulbs ON
S1 = Up,  S2, S3, S4 = Down Bulb 1 ON
S1, S2 = Up – S3, S4 = Down Bulb 2 ON
S1, S2, S3 = Up S4 = Down Bulb 3 ON

Keep in mind that two circuits may becomes in series for less than a second while changing the position of switches.

If you still unable to get the working of the tunnel circuit wiring, the following animation gif and video shows it perfectly.

Tunnel Wiring Circuit for Light Control using Switches animation

Video:

YouTube video player

Note: Use the suitable voltage and ampere rating of switch with appropriate wire size and proper size MCB according to the load rating.