How to Wire Solar Panel & Batteries in Parallel for 12V System
Parallel Connection of Solar Panels and Batteries with Automatic UPS System – 12V Installation
The 12V system is the most common solar panel wiring configuration used with batteries for small load residential application. Typically, to achieve a 12V DC to 120V/230V AC system, both the photovoltaic (PV) panels and batteries are connected in parallel. This setup is widely used with a 12V solar charge controller and an automatic inverter/UPS to support AC loads (120–230V), battery charging, and direct DC loads such as DC-operated appliances.
Solar panels and batteries wiring configuration system are commonly used for 12V, 24V, 36V, and 48V variants. If you want to increase the system’s capacity (either to run the load for a longer time or to handle a higher load), you must wire the components in a parallel configuration.
For example, if a single 12V battery powers a ceiling fan for 6 hours, connecting a second identical battery in parallel will allow the fan to run for approximately 12 hours. Similarly, using two solar panels connected in parallel will result in faster battery charging and the ability to support more load.
This parallel wiring method is essential for 12V systems, including 12V charge controllers and inverters. Therefore, two or more solar panels and batteries (each rated at 12V DC) are connected in parallel to maintain system voltage while increasing current capacity.
We know that in a parallel connection, the voltage remains the same, while the current increases. In other words, currents are additive in a parallel configuration.
V1 = V2 = V3 … = Vn
IT = I1 + I2 + I3 … + In
This means that when solar panels or batteries are connected in parallel, the voltage level stays the same, but the current capacity increases. For batteries, this increase is measured in ampere-hours (Ah), and for solar panels, in amperes (A).
For example:
If you connect two solar panels or two batteries, each rated at 12V DC, 120W, and 10A, in parallel, the combined output will be:
- Voltage (V) = 12V (same as a single unit)
- Current (I) = 10A + 10A = 20A
- Power (P) = 12V × 20A = 240W
Similarly, for batteries, if each is rated at 12V, 100Ah, then two connected in parallel will result in:
- Voltage (V) = 12V
- Capacity (Ah) = 100Ah + 100Ah = 200Ah
It shows that the voltage level is same for both solar panels and batteries while the ampere hour (Ah) capacity of batteries is increased when connected in parallel.
In a parallel configuration, the voltage remains constant at 12V (both for PV panels and batteries), while the current capacity increases. This configuration is ideal for systems using a 12V UPS/inverter and solar charge controller. It allows both energy generation (via solar panels) and energy storage (via batteries) to operate efficiently and seamlessly.
During normal daylight conditions, the DC to AC inverter is powered by the solar panels directly. In case of low sunlight, shading, or at night, the inverter draws power from the battery bank. The inverter then converts 12V DC into 120V/240V AC (for US systems) or 230V AC (for UK/EU systems), depending on the regional AC voltage requirements. This AC power can then be used to run standard electrical loads such as light bulbs, fans, etc.
Additionally, DC-operated devices can be connected directly to the DC load terminals of the charge controller for efficient and lossless operation.
Wiring Parallel Solar Panels and Batteries:
To connect two or more solar panels and batteries in parallel, simply connect the positive terminal of one panel or battery to the positive terminal of the other, and the negative terminal to the negative terminal, as shown in the diagram below.
In the following wiring diagram:
- Two 12V, 10A, 120W solar panels are connected in parallel.
- They charge two 12V, 100Ah batteries that are also connected in parallel.
- During the day, solar panels power the AC load via the inverter and charge the battery bank.
- During night or cloudy conditions (no sunlight), the stored energy in batteries powers the inverter, which continues to supply AC power to the load.
- The entire process is automatic, handled by the UPS/inverter, with no manual switching or ATS (Automatic Transfer Switch) required.

Related Posts:
- A Complete Guide about Solar Panel Installation. Step by Step Procedure with Calculation and Image
- Blocking Diode and Bypass Diodes in a Solar Panel Junction Box
- Basic Components Needed for Solar Panel System Installation
- How Much Watts Solar Panel You Need for Home Appliances?
- How to Design and Install a Solar PV System? With Solved Example
- Solar Panel Wiring and Installation Diagrams







Most Solar panels come in 12/24/36 etc volts.If you are using a 12V system and want to add extra capacity to your system you will wire your batteries in parallel. Sunnyvale solar panel.
Why is charge controller being used with inverter during solar connection. But when connecting with main power supply only inverter is been used without charge controller.
If you use 5 Amps x 24h in a 120Ah battery bank, you’re killing this bank. The max use of a battery bank, to increase its life, its 25%. So, that 120 / 4 (25%) = 30, and 30 / 5 Amps = 6 hours.
According to your calculations on determining the panel size,are the 4hrs assumed or standard…& While you advise…a great day.
Good Day,
Kindly advise if you have in stock and available to supply the items below
Sealed lead acid Battery or AGM battery12v /100AH to 200AH
Or rather let us know if you have ultimate item that similar to our request
Scott George
Galp Ventures
981 Auraria Pkwy #15
Denver, CO 80204
Is it advice able to use 3 12v/200amps battery and 12v/100amp on 4.5kva inverter
No, You have to use 200amps all through.
just wondering if I have two separate solar panel systems (folding type used for camping) and running my two batteries as a parallel system can i use both separate solar system to charge the batteries at the same time.
Sir, I have a solar system installed with inverter 1000W, solar panels 600w, 12w solar inverter hybrid 12v, battery one12v 150ah, please advise /help may I add in parallel one more battery 12v 150 ah, to increase back up, NO harm to inverter and home appliances of 220 v, like mixer, fan, led bulbs, etc. please advise help thanks and regards.
I would like to buy solar panel and battery for my laptop and one fan LED light how much that is cost is all the things
I am using 12v/165va two batteries in series, charged by solar panels 12v/200watt
I would like to run a garage fan 12/24 v or 240. Only to run when ther is enough light to generate power. No battery. Can it be done? And what would I need?
In this case, a simple 120W Solar panel with charge controller is enough.
Thank you for the wiring diagram.