Abnormal Operating Condition and Causes of Induction Motors

Abnormal Operating Condition and Causes of Induction Motors

Three phase induction motors are used on a large scale in industries. We may divide the abnormal conditions and causes of three phase motor this way.
Click image to enlarge
Abnormal Operating Condition and Causes of Induction Motors
Abnormal Operating Condition and Causes of Induction Motors (Photos by Siemens)

following are the Abnormal Operating Condition and Causes of Induction Motors

Mechanical Overload
  • Block the pump or gear system connected with motors
  • Damaged bearings or No Lubrication
  • Lock rotor or more time to starting the motor
  • Stalling the motor (When motor does not start due to heavy load)
  • In this case, motor is disconnected from supply as well as from mechanical load. After that, motor is started to satisfy the mechanical overlord condition.
Abnormal Supply Conditions
  • Low Supply Voltage
  • Unbalance supply voltage
  • Increase in Supply Voltage
  • Low Frequency (than normal frequency)
Faults in Supply Circuit
  • Not availability of three phases
  • Short circuit in supply cable
  • Damaged links of the contactor
  • Melted Fuse
Internal Faults in Motor
  • Phase to Phase faults
  • Phase to Earth faults
  • Open Circuit
  • Bad Insulation of The motor windings (in this case, motor is checked with megger)
➡️ READ FULL ARTICLE 📖

Electrical Technology

All about Electrical and Electronic Engineering & Technology. Join us on WhatsApp at Electrical Technology Official Channel, to receive the latest content, articles, and updates. You can also like and follow our social media networks below, or subscribe with your email to receive premium engineering articles in your mailbox.

4 Comments

  1. *Order* an H-bridge? I made one myself last night from raw tronsistars. Well I think I did. I made an H-bridge simulator anyway. It only lights LEDs so far. Also, I’ll probably blow out the tronsistars since I don’t know how to read the datasheet well enough to see what max current they’ll take.

  2. omprakash pawar says:

    Why induction motor is not run on synchronous. Speed?

  3. dileep shukla says:

    kindly explain how much check insulation resistance and phase to phase resistance?
    kindly tell us formula to check resistance by varios motors.

  4. Sathish Kumar.A says:

    usefull information about us

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button

Kindly permit ads on our free website.

It appears that you are using an ad blocker. We rely on advertising to support our website, provide free information, and sustain our services. Kindly consider whitelisting our website to allow ads.